![]() Take the 4th elbow fitting and connect the upward and sewer lines together. Likewise, install the 3rd elbow fitting with the bottom pipe and connect the upward pipe. Get a short pipe and insert it into the fitting after that.Īs for the bottom pipe, it must be shorter than the upward pipe. Carefully, connect it to the other end of the downward pipe. If the drain goes straight downwards, it can be used as a downward pipe. Connect both ends of the fitting after applying the coating and glue. Now, we’re going to install the 1st fitting between the condensate and downward lines. But you can’t just connect the fittings as they’ll be loose.Ĭoat each pipe and fit it with a PVC cleaner. You have to install 4 elbow fittings and create a U shape now. You can use a pipe cutter or a hacksaw to cut the pipe. Then place the bucket beneath the area you’re going to cut. Now, choose a place where you want to install a P-trap. Because there could be water inside the pipe. But before that, you’ll need to turn off the AC system.įirst, get a bucket and some rags. In this step, we’re going to cut the pipe into two and install some fittings. Manage these plumbing tools as soon as possible and we can get started! Step-01: Cut the Condensate Drain Rest assured! They are easy to manage and the fittings are really cheap. Gather the Necessary Toolsīefore we start, you’ll need certain tools for this DIY installation. But the P-trap installation process will be finished within an hour or so. You might have to work for a whole day to fix crumbling basement walls. Luckily, installing a P-trap is super easy. If you’re already worried, well don’t be. Now, we’re now going to install a P-trap. Install a P-trap By Yourself in 3 Easy Steps This is how the AC system can release water without any interruption. It gets pushed to the exit when new water is released. However, the opposite can’t happen because of the upward pipe being shorter.Īs a result, there’s always water in the U-shaped area. So, it uses momentum to climb the upward pipe. The water gets released from a higher height. They are called downward and upward pipes respectively. The U-shaped portion of a P-trap has two pipes. The science behind the P-trap is very simple. ![]() It has a simple mechanism that mustn’t be hindered during installation. It does that by preventing the condensate line from sucking air.Ī P-trap has several parts such as a ventilation line, U-shaped pipe, and drain exit. The P-trap nullifies the pressure imbalance which is created within the system. Although many manufacturers may not recommend a P-trap, they do encourage people to use it. This issue is solved by installing a P-trap. Because of the direct line, the sewer/outside gas enters the AC system. Just how draining water softener discharge outside is dangerous for the environment. To clear your confusion about direct connection, yes it’s really bad for your AC system. In most cases, experienced plumbers do not make this mistake.īut in some cases, the unfortunate happens. When investigating a condensate line, you might discover a direct connection to sewage. Conclusion Should AC Condensate Drain Be Connected To Sewage Directly?
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |